   Most of our systems are designed for Power devices. But we deliver also test systems for different devices, like schottky diodes , opto couplers or LEDs. For example :

 

TEST SYSTEMS FOR VDE 0884

Test system for safety testing for opto couplers according to VDE 0884, level I and II
Test capacity : 240 DUTs
Test chamber : 1
Temperature range : 50°C to 175°C

Input current Id : 0 to 100mA
Output voltage Vce : 0 to 300V
Output current Ice : 0 to 10mA
PULSE LIFE TEST FOR LEDs
Test capacity : 300 to 1500 DUTs
Pulse current : 0 to 3A, 0 to 5A
Pulse width : 10µs to 10ms
Frequency : 1Hz to 1kHz, 1Hz to 10kHz
Test temperature : Room temperature or 25°C to 100°C

 


Ing. Buero s.r.o., Lozická 129, 190 16 Újezd nad Lesy - Praha 9, Czech republic

tel./fax : +420 281 971 605

web : www.ingbuero.cz                 e-mail :  ingbuero@ingbuero.cz